Research on Leakage Inspection Technology of Precast ConcreteResidential Building Exterior Wall
About the author:
Shanghai Key Laboratory of Engineering Structure Safety, Shanghai Research Institute ofBuilding Sciences Co., Ltd., Shanghai 200032, China
Abstract:
Aiming at the leakage problem of the precast concrete residential building exterior wall, thesite inspection technology of both leakage detector and microwave hygrometer was explored. The researchresults show that the leakage detector can be used for the leakage qualitative inspection of both the precastshear wall with sandwich insulation and ordinary precast shear wall vertical joints, and the microwavehygrometer can be used for the leakage qualitative inspection of both the precast shear wall with sandwichinsulation and ordinary precast shear wall bottom joints. The inspection results can reflect the flowdirection and approximate accumulation range of seepage water,which is conducive to taking effectiveplugging measures.